Zeronix Technology supplies, installs, and maintains intrusion detection and burglar alarm systems across Dubai and the UAE — motion detectors, door and window contacts, glass break sensors, Honeywell, Bosch, and Paradox control panels, with 24/7 central station monitoring and fast-response AMC support.
From detector selection and zone planning to control panel installation, 24/7 monitoring connection, and ongoing AMC — we handle every layer of your intrusion protection.
Supply and install commercial-grade alarm control panels — Honeywell (DSC), Bosch, Paradox, and Texecom — sized for your zone count with battery backup, tamper protection, and dual communication paths. Systems are commissioned with correct entry and exit delays, alarm sounder placement, and keypad positions for operational ease without compromising security.
Honeywell · Bosch · Paradox · TexecomInstall passive infrared (PIR), dual-technology (PIR + microwave), and volumetric detectors to cover interior spaces with minimal false alarms. Dual-tech detectors require both PIR and microwave detection simultaneously before triggering — dramatically reducing nuisance alarms from temperature fluctuations, A/C airflow, or small animals while maintaining reliable intruder detection.
PIR · Dual-Tech · Volumetric · Pet-ImmuneFit magnetic reed contacts to every door, window, skylight, and roof hatch in your perimeter — providing immediate zone activation if any opening is forced or opened while the system is armed. Suitable for roller shutters, fire doors, overhead doors, and emergency exits with shock sensors added to detect impact before a breach completes.
Reed Contacts · Shock Sensors · Roller Shutters · SkylightsInstall acoustic glass break detectors that recognise the specific frequency signature of breaking glass — covering multiple panes from a single detector in open-plan spaces. Unlike magnetic contacts which only trigger after a window is opened, glass break detectors activate on the break itself, alerting the panel before an intruder can enter through shattered glass.
Acoustic · Multi-Pane Coverage · Shopfronts · FacadesConnect your alarm system to a professional monitoring centre via IP primary path and GSM backup — so trained operators receive alarm events within seconds, verify alerts, attempt to reach your key holders, and dispatch security response if required. Central station monitoring provides a response layer that a self-monitored phone-only alarm cannot match when you're unreachable or during a simultaneous mobile network outage.
IP + GSM Dual Path · Verified Response · Key Holder ContactAnnual maintenance contracts covering scheduled testing of every detector and zone, sounder output verification, battery load testing and replacement before failure, panel firmware updates, communication path testing to the monitoring centre, and tamper condition checks — with remote diagnostics and priority on-site response for faults. An untested alarm is an alarm you cannot rely on.
AMC · Battery Testing · Zone Testing · Priority ResponseWalk the premises to identify all entry and exit points, vulnerable areas, high-value assets, and existing infrastructure. Assess structural factors that affect detector placement — ceiling height, A/C vents, obstructions — and confirm cable routing paths and power availability before designing the system.
Design the zone layout — assigning detectors, contacts, and sensors to logical zones that reflect how your premises is used, allowing partial arming of unoccupied areas. Specify the control panel, keypad locations, sounder positions, and communication module. Provide an itemised proposal with equipment specifications and pricing before any work begins.
Install all detectors, contacts, panel, keypads, and sounders — running concealed wiring where possible. Commission the panel: program zones, entry and exit delays, user codes, and alarm responses. Test every zone individually and verify monitoring centre communication. Confirm false alarm prevention measures are correctly set before handover.
Train all key holders on arming, disarming, part-arming, and bypassing zones. Provide user code management instructions. Confirm monitoring centre key holder details and test the full alarm-to-response sequence. Issue as-built zone documentation and user guide. Set the AMC schedule and support contact before leaving site.
| Feature | Basic Alarm | Monitored Alarm | Smart Integrated |
|---|---|---|---|
| On-Site Sounder | Yes | Yes | Yes |
| Mobile Phone Alert | App Only | App + Centre | App + Centre |
| 24/7 Professional Monitoring | No | Yes | Yes |
| Security Response Dispatch | No | Yes | Yes |
| CCTV Integration | No | Optional | Full Integration |
| Access Control Link | No | No | Zone Lock-Down |
Perimeter magnetic contacts on all entrance doors and windows, interior PIR coverage of server rooms and high-value areas, part-arming for out-of-hours partial occupancy, and central station monitoring that escalates to your facilities team if an alarm triggers during non-business hours without generating a police response for every delayed employee.
Long-range volumetric PIR detectors covering large open-floor areas without the wiring density of multiple standard PIRs, shock sensors on roller shutters and loading bay doors, outdoor weatherproof PIR coverage of perimeter access points, and separate arming zones for staff working in one area while the rest of the warehouse is fully armed.
Glass break detectors covering shopfront display windows, magnetic contacts on service entrances and stockrooms, duress code functionality allowing staff to silently signal the monitoring centre under coercion, and panic buttons at checkout positions for immediate silent alarm dispatch — providing comprehensive retail security without visible hardware deterring customers.
Separate arming zones allowing after-hours security of pharmacy, records, and equipment storage areas while wards remain accessible to night-shift staff — with duress alarm coverage at reception and consulting rooms, and monitoring centre response calibrated to avoid inappropriate emergency service dispatch for internal staff movements.
High-sensitivity PIR and door contact protection for server rooms and comms rooms with 24/7 armed status — regardless of building occupancy — triggering immediate central station alerts and CCTV camera activation on any access attempt, with audit logs of all arm, disarm, and zone activation events for compliance documentation.
After-hours perimeter alarm for administrative buildings, server rooms, and laboratories — with separate zones for canteens and sports facilities that may be used by outside organisations after school hours. Staff duress alarm buttons at reception and principal's office, with monitoring centre protocol calibrated for educational institution operational hours.
We design zone layouts that reflect your operational patterns — allowing you to arm the warehouse while the office is staffed, or protect the server room 24/7 regardless of building occupancy. A poorly zoned alarm forces a choice between leaving areas unprotected or generating constant false alarms from staff movement.
We specify dual-technology detectors in environments with A/C, high ceilings, or heat sources, correctly mask PIRs near windows and vents, and set entry/exit delays to realistic values. Most false alarms are caused by poor installation decisions — we eliminate them at the design stage, not by reducing sensitivity.
All monitored systems are connected via IP primary path and GSM/4G backup — so if your internet connection fails during a burglary, the alarm still reaches the monitoring centre via mobile network. A single-path alarm that relies only on broadband has a critical vulnerability that determined intruders can exploit by cutting the line.
When an alarm zone triggers, connected CCTV cameras begin recording and the monitoring centre receives a live video feed for visual verification — reducing unnecessary police or security dispatch and providing evidence for insurance claims. Integration with access control can automatically lock down doors on alarm activation.
We size and test the panel backup battery for your zone count and sounder load — and replace it on a managed schedule before it degrades. A failed battery means your alarm has no protection during a mains power cut, which is exactly the scenario a determined intruder may engineer before attempting a breach.
When a zone develops a fault or a sounder fails, your security system has a gap. Our AMC provides remote panel diagnostics within 2 hours and priority on-site attendance for critical faults — with a dedicated engineer contact, not a call centre. Regular preventive maintenance catches battery degradation, detector faults, and wiring issues before they become failures.
A burglar alarm that hasn't been tested, has a flat battery, or isn't monitored is a noise maker — not a security system. Book a free site survey with a Zeronix engineer and get a proper intrusion detection solution.